{"id":3639,"date":"2026-04-14T03:30:09","date_gmt":"2026-04-14T02:30:09","guid":{"rendered":"https:\/\/www.nickelcasting.com\/?p=3639"},"modified":"2026-04-14T03:30:16","modified_gmt":"2026-04-14T02:30:16","slug":"monel-k-500-corrosion-resistance-in-sulfuric-acid","status":"publish","type":"post","link":"https:\/\/www.nickelcasting.com\/ko\/monel-k-500-corrosion-resistance-in-sulfuric-acid\/","title":{"rendered":"Monel K-500 Corrosion Resistance in Sulfuric Acid"},"content":{"rendered":"<p data-start=\"239\" data-end=\"877\">When engineers evaluate <strong data-start=\"263\" data-end=\"316\">Monel K-500 corrosion resistance in sulfuric acid<\/strong>, the right answer is rarely a simple yes or no. Monel K-500 is a precipitation-hardened nickel-copper alloy, essentially a higher-strength evolution of <a href=\"https:\/\/www.nickelcasting.com\/ja\/%e3%83%8b%e3%83%83%e3%82%b1%e3%83%ab%e5%90%88%e9%87%91\/%e3%83%a2%e3%83%8d%e3%83%ab%e5%90%88%e9%87%91\/monel-400\/\">\ubaa8\ub12c 400<\/a>, with aluminum and titanium added for age hardening. That gives it a very attractive combination of corrosion resistance, strength, and galling resistance. However, sulfuric acid service is unforgiving. In this environment, alloy selection is controlled less by tensile strength and more by electrochemical behavior, surface film stability, oxidizing contamination, and the actual process envelope.<\/p>\n<p data-start=\"879\" data-end=\"1459\">\uadf8\ub807\uae30 \ub54c\ubb38\uc5d0 <strong data-start=\"891\" data-end=\"944\">Monel K-500 corrosion resistance in sulfuric acid<\/strong> must be judged case by case. A buyer looking only at the alloy family name can easily make the wrong call. K-500 may perform acceptably in certain low-temperature, low-oxidizing, carefully controlled sulfuric acid streams. But once temperature rises, acid concentration shifts, or dissolved oxygen and ferric ions enter the system, the corrosion mechanism can change quickly. What looks acceptable in a static lab note may become a maintenance problem in a real pickling line, acid transfer skid, or pump assembly.<\/p>\n<p data-start=\"1461\" data-end=\"1853\">From an engineering standpoint, the first thing to remember is that Monel K-500 does not rely on a chromium-rich passive film the way many stainless steels or high-chromium <a href=\"https:\/\/www.nickelcasting.com\/ja\/%e3%83%8b%e3%83%83%e3%82%b1%e3%83%ab%e5%90%88%e9%87%91\/\">\ub2c8\ucf08 \ud569\uae08<\/a> do. In reducing media, nickel-copper alloys can be useful. In hotter or more oxidizing sulfuric acid, that advantage narrows or disappears. This distinction matters more than many procurement sheets admit.<\/p>\n<p data-start=\"1855\" data-end=\"2018\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-3640\" src=\"https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/282.jpg\" alt=\"Monel K-500 Corrosion Resistance in Sulfuric Acid\" width=\"1200\" height=\"800\" srcset=\"https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/282.jpg 1200w, https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/282-300x200.jpg 300w, https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/282-1024x683.jpg 1024w, https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/282-768x512.jpg 768w, https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/282-18x12.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/p>\n<h2 data-section-id=\"193fzer\" data-start=\"2020\" data-end=\"2091\">Why Monel K-500 Corrosion Resistance in Sulfuric Acid Is Conditional<\/h2>\n<p data-start=\"2093\" data-end=\"2524\">The technical challenge with <strong data-start=\"2122\" data-end=\"2175\">Monel K-500 corrosion resistance in sulfuric acid<\/strong> is that sulfuric acid is not one environment. A 5% acid stream at ambient temperature behaves very differently from 50% acid at elevated temperature. Add aeration, ferric sulfate, copper salts, chlorides, or intermittent evaporation, and the severity can increase further. In practical service, five variables usually decide whether K-500 survives:<\/p>\n<p data-start=\"2526\" data-end=\"2740\">First, <strong data-start=\"2533\" data-end=\"2555\">acid concentration<\/strong>. Dilute sulfuric acid may be manageable under controlled conditions, but intermediate and concentrated ranges often become much more aggressive, especially once film stability is lost.<\/p>\n<p data-start=\"2742\" data-end=\"3034\">Second, <strong data-start=\"2750\" data-end=\"2765\">temperature<\/strong>. Corrosion rates that appear moderate at room temperature can accelerate sharply above roughly process-warm conditions. This is often where field failures begin, not because the alloy \u201csuddenly became bad,\u201d but because the original selection window was too optimistic.<\/p>\n<p data-start=\"3036\" data-end=\"3284\">Third, <strong data-start=\"3043\" data-end=\"3070\">oxidizing contamination<\/strong>. Pure sulfuric acid is one thing; sulfuric acid contaminated with ferric ions, cupric ions, nitric species, or entrained air is another. These oxidizers can shift the corrosion potential and promote faster attack.<\/p>\n<p data-start=\"3286\" data-end=\"3472\">Fourth, <strong data-start=\"3294\" data-end=\"3315\">flow and deposits<\/strong>. Clean, controlled flow is easier on the alloy than under-deposit zones, stagnant pockets, gasket crevices, and pump dead legs. Localized chemistry matters.<\/p>\n<p data-start=\"3474\" data-end=\"3754\">Fifth, <strong data-start=\"3481\" data-end=\"3508\">metallurgical condition<\/strong>. The precipitation-hardening treatment that gives K-500 its mechanical strength does not automatically improve acid resistance. In fact, for sulfuric acid duty, the added strength should never be treated as proof of broader chemical suitability.<\/p>\n<h2 data-section-id=\"b7zplf\" data-start=\"3756\" data-end=\"3827\">Practical Guide to Monel K-500 Corrosion Resistance in Sulfuric Acid<\/h2>\n<p data-start=\"3829\" data-end=\"4036\">The table below is not a substitute for coupon testing, but it reflects how experienced materials engineers usually screen <strong data-start=\"3952\" data-end=\"4005\">Monel K-500 corrosion resistance in sulfuric acid<\/strong> before they recommend a trial.<\/p>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"4038\" data-end=\"5275\">\n<thead data-start=\"4038\" data-end=\"4124\">\n<tr data-start=\"4038\" data-end=\"4124\">\n<th class=\"\" data-start=\"4038\" data-end=\"4064\" data-col-size=\"md\">\ud669\uc0b0 \uc0c1\ud0dc<\/th>\n<th class=\"\" data-start=\"4064\" data-end=\"4101\" data-col-size=\"sm\">General assessment for Monel K-500<\/th>\n<th class=\"\" data-start=\"4101\" data-end=\"4124\" data-col-size=\"lg\">Engineering comment<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"4139\" data-end=\"5275\">\n<tr data-start=\"4139\" data-end=\"4318\">\n<td data-start=\"4139\" data-end=\"4188\" data-col-size=\"md\">Dilute acid, ambient temperature, low aeration<\/td>\n<td data-start=\"4188\" data-end=\"4215\" data-col-size=\"sm\"><strong data-start=\"4190\" data-end=\"4214\">Conditionally usable<\/strong><\/td>\n<td data-start=\"4215\" data-end=\"4318\" data-col-size=\"lg\">Possible for limited service if the stream is clean and reducing; verify with lab or field coupons.<\/td>\n<\/tr>\n<tr data-start=\"4319\" data-end=\"4504\">\n<td data-start=\"4319\" data-end=\"4385\" data-col-size=\"md\">Dilute to moderate acid, ambient to mildly elevated temperature<\/td>\n<td data-start=\"4385\" data-end=\"4402\" data-col-size=\"sm\"><strong data-start=\"4387\" data-end=\"4401\">Borderline<\/strong><\/td>\n<td data-start=\"4402\" data-end=\"4504\" data-col-size=\"lg\">Small increases in temperature or oxidizing contamination can move the alloy out of a safe window.<\/td>\n<\/tr>\n<tr data-start=\"4505\" data-end=\"4690\">\n<td data-start=\"4505\" data-end=\"4567\" data-col-size=\"md\">Moderate acid with dissolved oxygen or ferric contamination<\/td>\n<td data-start=\"4567\" data-end=\"4583\" data-col-size=\"sm\"><strong data-start=\"4569\" data-end=\"4582\">High risk<\/strong><\/td>\n<td data-start=\"4583\" data-end=\"4690\" data-col-size=\"lg\">General corrosion can rise quickly; localized attack in crevices or stagnant zones becomes more likely.<\/td>\n<\/tr>\n<tr data-start=\"4691\" data-end=\"4890\">\n<td data-start=\"4691\" data-end=\"4752\" data-col-size=\"md\">Hot sulfuric acid, especially above moderate concentration<\/td>\n<td data-start=\"4752\" data-end=\"4782\" data-col-size=\"sm\"><strong data-start=\"4754\" data-end=\"4781\">Generally not preferred<\/strong><\/td>\n<td data-start=\"4782\" data-end=\"4890\" data-col-size=\"lg\">K-500 is rarely the first-choice alloy here; higher-alloy Ni-Cr-Mo systems are usually screened instead.<\/td>\n<\/tr>\n<tr data-start=\"4891\" data-end=\"5056\">\n<td data-start=\"4891\" data-end=\"4936\" data-col-size=\"md\">Cyclic wet-dry or evaporative acid service<\/td>\n<td data-start=\"4936\" data-end=\"4957\" data-col-size=\"sm\"><strong data-start=\"4938\" data-end=\"4956\">Poor candidate<\/strong><\/td>\n<td data-start=\"4957\" data-end=\"5056\" data-col-size=\"lg\">Local concentration spikes and deposit formation can make apparent \u201cmild\u201d acid far more severe.<\/td>\n<\/tr>\n<tr data-start=\"5057\" data-end=\"5275\">\n<td data-start=\"5057\" data-end=\"5132\" data-col-size=\"md\">\uace0\uac15\ub3c4 <a href=\"https:\/\/www.nickelcasting.com\/ja\/product-forms\/fasteners\/\">\ud328\uc2a4\ub108<\/a> or shafts with combined stress and acid exposure<\/td>\n<td data-start=\"5132\" data-end=\"5158\" data-col-size=\"sm\"><strong data-start=\"5134\" data-end=\"5157\">Needs extra caution<\/strong><\/td>\n<td data-start=\"5158\" data-end=\"5275\" data-col-size=\"lg\">Mechanical strength helps load capacity, not necessarily corrosion margin; test the exact heat-treated condition.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"5277\" data-end=\"5678\">One of the most common specification mistakes is to assume that because Monel K-500 is stronger than Monel 400, it must also be better in sulfuric acid. That is not a safe assumption. Strength is valuable for shafts, springs, pump sleeves, and marine hardware. But in sulfuric acid, the controlling question is whether the alloy remains electrochemically stable under the real chemistry of the system.<\/p>\n<h2 data-section-id=\"108bapn\" data-start=\"5680\" data-end=\"5746\">Monel K-500 Corrosion Resistance in Sulfuric Acid vs. Monel 400<\/h2>\n<p data-start=\"5748\" data-end=\"6250\">A more useful comparison is <strong data-start=\"5776\" data-end=\"5829\">Monel K-500 corrosion resistance in sulfuric acid<\/strong> versus Monel 400 in the same stream. In many general environments, K-500 is often described as having corrosion resistance broadly similar to Monel 400, while adding higher strength. Yet \u201cbroadly similar\u201d does not mean \u201cinterchangeable without review.\u201d The age-hardening additions and heat treatment introduce microstructural complexity that a corrosion engineer cannot ignore, especially when sulfuric acid is involved.<\/p>\n<p data-start=\"6252\" data-end=\"6323\">For equipment designers, the selection logic should be straightforward:<\/p>\n<ul data-start=\"6325\" data-end=\"6865\">\n<li data-section-id=\"1kl9ol9\" data-start=\"6325\" data-end=\"6481\">If the job is primarily <strong data-start=\"6351\" data-end=\"6365\">mechanical<\/strong>, and the acid exposure is secondary, intermittent, cool, and well characterized, K-500 may remain on the shortlist.<\/li>\n<li data-section-id=\"1l05b3t\" data-start=\"6482\" data-end=\"6641\">If the job is primarily <strong data-start=\"6508\" data-end=\"6520\">chemical<\/strong>, and the sulfuric acid is hot, contaminated, oxidizing, or concentration-variable, K-500 usually moves down the ranking.<\/li>\n<li data-section-id=\"vz191u\" data-start=\"6642\" data-end=\"6865\">If failure consequences are high, the correct path is not \u201cchoose the strongest Monel grade.\u201d The correct path is coupon testing, impurity review, and a temperature-concentration map built around the actual process fluid.<\/li>\n<\/ul>\n<p data-start=\"6867\" data-end=\"7323\">This is where experienced suppliers can add real value. A serious engineering conversation should cover acid concentration swings, startup and shutdown conditions, idle periods, metal ion contamination, weld details, crevice geometry, and whether the part is in a solution-treated or age-hardened condition. Those are the details that decide whether <strong data-start=\"7217\" data-end=\"7270\">Monel K-500 corrosion resistance in sulfuric acid<\/strong> is acceptable on paper only, or reliable in service.<\/p>\n<p data-start=\"7325\" data-end=\"7493\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-3641\" src=\"https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/283.jpg\" alt=\"Monel K-500 Corrosion Resistance in Sulfuric Acid\" width=\"1200\" height=\"800\" srcset=\"https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/283.jpg 1200w, https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/283-300x200.jpg 300w, https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/283-1024x683.jpg 1024w, https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/283-768x512.jpg 768w, https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/283-18x12.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/p>\n<h2 data-section-id=\"x0ne3i\" data-start=\"7495\" data-end=\"7524\">Final Engineering Judgment<\/h2>\n<p data-start=\"7526\" data-end=\"8057\">\uadf8\ub798\uc11c <strong data-start=\"7533\" data-end=\"7586\">Monel K-500 corrosion resistance in sulfuric acid<\/strong> good? The disciplined answer is: good only in a narrow and controlled envelope. It is not a universal sulfuric acid alloy, and it should not be marketed that way to engineers or buyers. Where the acid is dilute, cool, relatively clean, and non-oxidizing, K-500 may be a workable option when high strength is also needed. Where the acid is hot, concentrated, aerated, contaminated, or variable, the risk increases fast and alternative alloys usually deserve first review.<\/p>\n<p data-start=\"8059\" data-end=\"8387\">For buyers, this is the key takeaway: do not purchase K-500 for sulfuric acid service from a generic alloy table alone. Ask for condition-specific guidance, expected corrosion mode, and whether the recommendation is backed by coupon logic. At 28Nickel, that is exactly the level of discussion worth having before a PO is issued.<\/p>\n<h2 data-section-id=\"11wu1ks\" data-start=\"8389\" data-end=\"8403\">\uad00\ub828 Q&amp;A<\/h2>\n<h3 data-section-id=\"180g4m4\" data-start=\"8405\" data-end=\"8477\">1) Is Monel K-500 better than 316L stainless steel in sulfuric acid?<\/h3>\n<p data-start=\"8478\" data-end=\"8775\">Often yes in some reducing, low-oxidizing sulfuric acid situations, because 316L can lose corrosion margin quickly. But for hotter or more oxidizing sulfuric acid, neither 316L nor K-500 may be the best answer. Alloy selection should be based on the actual chemistry, not a simple grade hierarchy.<\/p>\n<h3 data-section-id=\"jputkv\" data-start=\"8777\" data-end=\"8861\">2) Does the higher strength of Monel K-500 mean better sulfuric acid resistance?<\/h3>\n<p data-start=\"8862\" data-end=\"9105\">No. Higher strength improves load-bearing capability, wear resistance, and hardware performance. It does not automatically improve sulfuric acid corrosion behavior. Mechanical advantage and chemical compatibility are separate design questions.<\/p>\n<h3 data-section-id=\"1i5b8p2\" data-start=\"9107\" data-end=\"9190\">3) What should a buyer confirm before ordering K-500 for sulfuric acid service?<\/h3>\n<p data-start=\"9191\" data-end=\"9470\">Confirm acid concentration range, operating and upset temperature, oxidizing contaminants, flow pattern, crevice exposure, required product form, and heat-treated condition. For critical service, request coupon testing or prior service evidence that matches your process closely.<\/p>","protected":false},"excerpt":{"rendered":"<p>When engineers evaluate Monel K-500 corrosion resistance in sulfuric acid, the right answer is rarely a simple yes or no. Monel K-500 is a precipitation-hardened nickel-copper alloy, essentially a higher-strength evolution of Monel 400, with aluminum and titanium added for age hardening. That gives it a very attractive combination of corrosion resistance, strength, and galling [&hellip;]<\/p>","protected":false},"author":1,"featured_media":3641,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[3],"tags":[],"class_list":["post-3639","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"spectra_custom_meta":{"_edit_lock":["1776133676:1"],"_edit_last":["1"],"rank_math_internal_links_processed":["1"],"rank_math_seo_score":["69"],"rank_math_focus_keyword":["Monel K-500 Corrosion Resistance in Sulfuric Acid"],"rank_math_description":["Unsure about Monel K-500 corrosion resistance in sulfuric acid? See where it works, where it fails, and what buyers often miss."],"_thumbnail_id":["3641"],"_wp_page_template":["default"],"ilj_blacklistdefinition":["a:0:{}"],"ilj_linkdefinition":["a:1:{i:0;s:49:\"Monel K-500 Corrosion Resistance in Sulfuric Acid\";}"],"site-sidebar-layout":["default"],"ast-site-content-layout":["default"],"site-content-style":["default"],"site-sidebar-style":["default"],"theme-transparent-header-meta":["default"],"astra-migrate-meta-layouts":["set"],"_uag_page_assets":["a:9:{s:3:\"css\";s:263:\".uag-blocks-common-selector{z-index:var(--z-index-desktop) !important}@media (max-width: 976px){.uag-blocks-common-selector{z-index:var(--z-index-tablet) !important}}@media (max-width: 767px){.uag-blocks-common-selector{z-index:var(--z-index-mobile) !important}}\n\";s:2:\"js\";s:0:\"\";s:18:\"current_block_list\";a:8:{i:0;s:11:\"core\/search\";i:1;s:10:\"core\/group\";i:2;s:12:\"core\/heading\";i:3;s:17:\"core\/latest-posts\";i:4;s:20:\"core\/latest-comments\";i:5;s:13:\"core\/archives\";i:6;s:15:\"core\/categories\";i:7;s:10:\"core\/image\";}s:8:\"uag_flag\";b:0;s:11:\"uag_version\";s:10:\"1776155711\";s:6:\"gfonts\";a:0:{}s:10:\"gfonts_url\";s:0:\"\";s:12:\"gfonts_files\";a:0:{}s:14:\"uag_faq_layout\";b:0;}"],"_uag_css_file_name":["uag-css-3639.css"],"_elementor_page_assets":["a:0:{}"]},"uagb_featured_image_src":{"full":["https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/283.jpg",1200,800,false],"thumbnail":["https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/283-150x150.jpg",150,150,true],"medium":["https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/283-300x200.jpg",300,200,true],"medium_large":["https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/283-768x512.jpg",768,512,true],"large":["https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/283-1024x683.jpg",1024,683,true],"1536x1536":["https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/283.jpg",1200,800,false],"2048x2048":["https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/283.jpg",1200,800,false],"trp-custom-language-flag":["https:\/\/www.nickelcasting.com\/wp-content\/uploads\/2026\/04\/283-18x12.jpg",18,12,true]},"uagb_author_info":{"display_name":"nickel","author_link":"https:\/\/www.nickelcasting.com\/ko\/author\/nickel\/"},"uagb_comment_info":0,"uagb_excerpt":"When engineers evaluate Monel K-500 corrosion resistance in sulfuric acid, the right answer is rarely a simple yes or no. Monel K-500 is a precipitation-hardened nickel-copper alloy, essentially a higher-strength evolution of Monel 400, with aluminum and titanium added for age hardening. That gives it a very attractive combination of corrosion resistance, strength, and galling&hellip;","_links":{"self":[{"href":"https:\/\/www.nickelcasting.com\/ko\/wp-json\/wp\/v2\/posts\/3639","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.nickelcasting.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.nickelcasting.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.nickelcasting.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.nickelcasting.com\/ko\/wp-json\/wp\/v2\/comments?post=3639"}],"version-history":[{"count":2,"href":"https:\/\/www.nickelcasting.com\/ko\/wp-json\/wp\/v2\/posts\/3639\/revisions"}],"predecessor-version":[{"id":3643,"href":"https:\/\/www.nickelcasting.com\/ko\/wp-json\/wp\/v2\/posts\/3639\/revisions\/3643"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.nickelcasting.com\/ko\/wp-json\/wp\/v2\/media\/3641"}],"wp:attachment":[{"href":"https:\/\/www.nickelcasting.com\/ko\/wp-json\/wp\/v2\/media?parent=3639"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.nickelcasting.com\/ko\/wp-json\/wp\/v2\/categories?post=3639"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.nickelcasting.com\/ko\/wp-json\/wp\/v2\/tags?post=3639"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}